Aluron / Aluminium entrance doors

AS 75 Door

The door branch of the AS 75 platform for thermally insulated external doors. Anti-bimetal solutions improve stability under temperature differences, with multiple threshold and fitting options.

AS 75 Door — Aluminium entrance doors

VERIFIED PARAMETERS

Door performance is geometry, temperature and hardware.

For a tall external door, insulation is only one part of the problem. Temperature differences, panel/glass weight, closer, electric lock and threshold determine real operation.

Max. vent size

3000 × 1400 mm

Max. vent weight

280 kg

Installation depth

75 mm

Infill / glazing

17–57 mm

Door Ud

from 0.93 W/m²K

Air permeability

class 4

Watertightness

E1200

Wind resistance

C2

Burglary resistance

RC2 / RC3

Sound insulation

up to 41 (-1; -5) dB

With AS 75 doors, thermal performance is only part of the picture. Leaf weight, hinges, lock, threshold and expected use determine the working configuration.

PROFILE CROSS-SECTION

AS 75 Door profile geometry in detail.

This image shows the system's profile geometry, chambers, thermal breaks and glazing zones. The final junction is selected for the opening scheme, glass build-up, dimensions and project loads.

Aluron AS 75 Door profile cross-section
OFFICIAL PROFILE SECTION / SYSTEM CUTAWAY

DOOR ARCHITECTURE

A thermally insulated entrance without bulky styling.

01

Multiple threshold solutions

02

Compatibility with contemporary door hardware

03

Anti-bimetal thermal strips for dimensional stability

04

Glass or panel infill configurations

DOOR DETAIL

Closer, lock and threshold are specified together.

For a premium entrance door we freeze the opening scheme, access control, closer, threshold, pull handle and power supply before fabrication.

01

Hardware

Vent weight and geometry must match hinges, closer and lock.

02

Threshold

Finished-floor level, sealing and accessibility are coordinated before ordering.

03

Electrical

Motor locks and access control require cable routes and service access.

BIFORIUM / PRACTICE

A system only works as a whole with glass, hardware and installation.

Threshold, rigid support, waterproofing and finished-floor level are fixed before production.

Open engineering details ↗
Glazing

For doors, infill weight, safety, solar load and the glass or panel edge are as important as thermal performance.

Hardware

Lock, hinges or pivot mechanism, closer, automation and access control are coordinated as one hardware package.

Installation detail

Threshold, rigid support, waterproofing and finished-floor level are fixed before production.

FAQ / SPECIFICATION

Questions to close before specification.

Can the system be selected only from catalogue performance?

No. Published values help shortlist options, but the finished element still has to be checked for size, glazing, weight, hardware, loads and installation detail.

Does every opening need the same glazing build-up?

Not necessarily. A south-facing elevation, a bedroom near traffic, a large fixed pane and an entrance leaf can require different glazing within the same project.

When should the installation detail be coordinated?

Before the final order. Finished-floor level, insulation, waterproofing, structural support and drainage can change the frame, threshold or final manufacturing size.

HOW TO READ THE DATA

Six values that shape the result.

A catalogue maximum is not the rating of every fabricated element. Classes depend on size, opening scheme, glazing, hardware and the tested configuration.

Ufthermal transmittance of the frame
Uw / Udthermal transmittance of the complete window or door
Rwsound reduction index in dB
RCburglary-resistance class
Air / Waterairtightness and driving-rain resistance
Windwind pressure and permitted deflection

ENTRANCE DOOR

Send the door size and desired hardware.

We will coordinate panel or glass, threshold, lock, closer, handle, access control and installation detail.

Send project ↗