Schüco / Mullion-transom façades

FWS 50

A high-performance 50 mm Schüco façade platform for vertical curtain walls and roof glazing. The broad system base supports integration of windows, doors, automation and solar shading components.

FWS 50 — Mullion-transom façades

SYSTEM PARAMETERS

50 mm face width — structural depth is project-specific.

The architect sees a 50 mm grid, while actual mullion and transom depth depends on span, grid, wind pressure and infill weight.

Visible width

50 mm

Mullion / transom depth

50–250 mm

Frame Uf

from 1.5 W/m²K

Infill / glazing

4–62 mm

Max. glass weight

up to 1080 kg

Sound insulation

up to 48 dB

Air permeability

AE

Watertightness

RE1200

Wind resistance

2.0 / 3.0 kN/m²

Impact resistance

I5 / E5

Burglary resistance

up to RC3

Roof inclination

5–90°

FWS 50 performance is defined by the façade scheme rather than a single profile. Mullion spans, transom spacing, glass and anchors need to be checked against the actual grid.

PROFILE CROSS-SECTION

FWS 50 profile geometry in detail.

This image shows the system's profile geometry, chambers, thermal breaks and glazing zones. The final junction is selected for the opening scheme, glass build-up, dimensions and project loads.

Schüco FWS 50 profile cross-section
OFFICIAL PROFILE SECTION / SYSTEM CUTAWAY

FAÇADE ARCHITECTURE

One platform, multiple envelope expressions.

01

Vertical curtain walls and roof glazing zones

02

Multiple pressure-plate and cover-cap designs

03

Integration of system windows, doors and solar shading

04

FWS 50.SI variant for higher thermal requirements

FAÇADE ENGINEERING

Profile depth follows structural calculation.

Mullion grid, façade height, wind pressure and glazing determine the actual profile depth. A generic profile section without these inputs proves very little.

01

Statics

We calculate mullion/transom deflection and load-bearing capacity under glass weight.

02

Glazing

Thickness, mass, setting blocks, edge loads and solar properties are coordinated.

03

Water & movement

Internal drainage levels, joints, thermal movement and building interfaces are designed together.

BIFORIUM / PRACTICE

A system only works as a whole with glass, hardware and installation.

Anchors, movement joints, pressure, drainage and roof/wall junctions are part of the system, not an afterthought.

Open engineering details ↗
Glazing

Façade glazing is selected for solar control, safety, spandrels, weight and allowable deflection; one build-up rarely suits the whole envelope.

Hardware

Opening inserts, actuators and ventilation are coordinated before the façade static design is finalised.

Installation detail

Anchors, movement joints, pressure, drainage and roof/wall junctions are part of the system, not an afterthought.

FAQ / SPECIFICATION

Questions to close before specification.

Can the system be selected only from catalogue performance?

No. Published values help shortlist options, but the finished element still has to be checked for size, glazing, weight, hardware, loads and installation detail.

Does every opening need the same glazing build-up?

Not necessarily. A south-facing elevation, a bedroom near traffic, a large fixed pane and an entrance leaf can require different glazing within the same project.

When should the installation detail be coordinated?

Before the final order. Finished-floor level, insulation, waterproofing, structural support and drainage can change the frame, threshold or final manufacturing size.

HOW TO READ THE DATA

Six values that shape the result.

A catalogue maximum is not the rating of every fabricated element. Classes depend on size, opening scheme, glazing, hardware and the tested configuration.

Ufthermal transmittance of the frame
Uw / Udthermal transmittance of the complete window or door
Rwsound reduction index in dB
RCburglary-resistance class
Air / Waterairtightness and driving-rain resistance
Windwind pressure and permitted deflection

FAÇADE REVIEW

Send façade grids and heights.

We need mullion/transom spacing, dimensions, building height, location, glazing and slab interfaces. From there we can define real section depths.

Send façade ↗