Reynaers Aluminium / Structural façade glazing

ConceptWall 50 SG

The Structural Glazed version of ConceptWall 50 for façades that should read as an almost continuous plane of glass without conventional exterior pressure caps. Insulating glass units are structurally bonded to cassettes, leaving controlled joints between modules.

ConceptWall 50 SG — Structural façade glazing

VERIFIED PARAMETERS

Structural glazing is a system of joints, bonding and movement.

CW 50-SG cannot be treated as “standard CW 50 without a cap”. Cassette type, structural silicone tolerances, IGU geometry, thermal movement and façade drainage all need to be engineered as one system.

Visible width

structural sealed glazing

Joint width

≈ 20 mm

Air permeability

class 4

Watertightness

RE1200

Wind resistance

A5*

Sound insulation

up to 45 (-2; -6) dB*

Infill / glazing

24–36 mm in SG cassettes*

Mullion / transom depth

42–300 mm

CW 50 SG figures refer to defined façade test arrangements. On an actual elevation, silicone bite, glass size, module grid and anchors are checked for each representative zone.

PROFILE CROSS-SECTION

ConceptWall 50 SG profile geometry in detail.

This image shows the system's profile geometry, chambers, thermal breaks and glazing zones. The final junction is selected for the opening scheme, glass build-up, dimensions and project loads.

Reynaers Aluminium ConceptWall 50 SG profile cross-section
OFFICIAL PROFILE SECTION / SYSTEM CUTAWAY

FAÇADE ARCHITECTURE

Where SG is justified.

01

Continuous glass appearance without external decorative pressure caps

02

Vertical façades and inclined zones within one system logic

03

Concealed drainage and solar shading integration options

04

High envelope performance when cassette fabrication and installation are properly controlled

FAÇADE ENGINEERING

The critical risks are mostly invisible.

For a structural façade the important calculations concern mullions, glass, structural sealant and building movement. The architectural joint must remain stable under wind and temperature change.

01

Mullion statics

Mullion and transom depth is selected against span, grid and design wind pressure.

02

Structural bonding

Cassette and silicone are designed as a load-bearing assembly; seal geometry follows the façade bonding technology.

03

Movement & water

We allow for thermal movement, drainage levels, joint sealing and controlled installation tolerances.

BUILT PROJECT

CW 50 SG in a demanding installation context.

At Oltamar the façade system was installed together with large-format glazing and mechanised lifting. Projects like this show why façade engineering and installation logistics must be coordinated from the start.

Oltamar installation
OLTAMAR / CALPE

Oltamar installation

Reynaers MasterPatio / ConceptWall 50 SG, vacuum lifting of large glass units and staged installation.

View project ↗

BIFORIUM / PRACTICE

A system only works as a whole with glass, hardware and installation.

Anchors, movement joints, pressure, drainage and roof/wall junctions are part of the system, not an afterthought.

Open engineering details ↗
Glazing

Façade glazing is selected for solar control, safety, spandrels, weight and allowable deflection; one build-up rarely suits the whole envelope.

Hardware

Opening inserts, actuators and ventilation are coordinated before the façade static design is finalised.

Installation detail

Anchors, movement joints, pressure, drainage and roof/wall junctions are part of the system, not an afterthought.

FAQ / SPECIFICATION

Questions to close before specification.

Can the system be selected only from catalogue performance?

No. Published values help shortlist options, but the finished element still has to be checked for size, glazing, weight, hardware, loads and installation detail.

Does every opening need the same glazing build-up?

Not necessarily. A south-facing elevation, a bedroom near traffic, a large fixed pane and an entrance leaf can require different glazing within the same project.

When should the installation detail be coordinated?

Before the final order. Finished-floor level, insulation, waterproofing, structural support and drainage can change the frame, threshold or final manufacturing size.

HOW TO READ THE DATA

Six values that shape the result.

A catalogue maximum is not the rating of every fabricated element. Classes depend on size, opening scheme, glazing, hardware and the tested configuration.

Ufthermal transmittance of the frame
Uw / Udthermal transmittance of the complete window or door
Rwsound reduction index in dB
RCburglary-resistance class
Air / Waterairtightness and driving-rain resistance
Windwind pressure and permitted deflection

FAÇADE REVIEW

Send façade elevations and grid lines.

For an initial review we need dimensions, mullion/transom grid, building height, glazing build-up and project location. From there we can discuss real profile depths and junctions.

Send façade ↗