Glazing is selected from actual Uw, solar, acoustic and safety requirements; large vents are also checked for glass weight.
Reynaers Aluminium / Aluminium windows
MasterLine 8 HI+
The high-insulation version of Reynaers’ flagship MasterLine 8 window platform. It is suited to contemporary homes and low-energy projects where clean architectural lines, large opening elements and predictable thermal performance need to work together.

VERIFIED PARAMETERS
Thermal performance without compromising the architecture.
HI+ is a high-insulation configuration within the MasterLine 8 platform. During design we look beyond the headline Uw and verify actual sash size, glazing build-up, frame ratio and the installation interface.
77 mm
from 97 mm
up to 1.3 W/m²K
up to 0.89 W/m²K
up to 2800 mm
up to 200 kg
class 4
E900
C5
up to 46 dB
The HI+ figures come from defined tested configurations. For a project window we still calculate frame fraction, glass build-up, edge zone and sash geometry.
PROFILE CROSS-SECTION
MasterLine 8 HI+ profile geometry in detail.
This image shows the system's profile geometry, chambers, thermal breaks and glazing zones. The final junction is selected for the opening scheme, glass build-up, dimensions and project loads.

APPLICATION
Where HI+ makes sense.
Low-energy and highly insulated private homes
Concealed hinges and clean interior lines
Glass corners, concealed drainage and motorisation as system options
Acoustic performance up to 46 dB in relevant test configurations
ENGINEERING
A catalogue Uw is only the starting point.
For large windows the outcome depends on much more than the frame. We model frame ratio, choose Ug and warm-edge spacer, and verify glass weight, deflection and support points.
Glazing
We specify Ug, solar control, heat-treated or laminated safety glass and spacer type to suit façade orientation.
Hardware
We check allowable sash weight and geometry; concealed hinges are considered when the architecture calls for cleaner lines.
Installation
A high-insulation window loses its value on a cold base or poorly sealed perimeter, so the junction is designed together with the element.
BIFORIUM / PRACTICE
A system only works as a whole with glass, hardware and installation.
Installation position, support, insulation, sealing and drainage belong in the specification rather than being improvised on site.
Open engineering details ↗Hardware limits the viable vent geometry just as much as the profile. Concealed hinges and automation need early coordination.
Installation position, support, insulation, sealing and drainage belong in the specification rather than being improvised on site.
FAQ / SPECIFICATION
Questions to close before specification.
Can the system be selected only from catalogue performance?
No. Published values help shortlist options, but the finished element still has to be checked for size, glazing, weight, hardware, loads and installation detail.
Does every opening need the same glazing build-up?
Not necessarily. A south-facing elevation, a bedroom near traffic, a large fixed pane and an entrance leaf can require different glazing within the same project.
When should the installation detail be coordinated?
Before the final order. Finished-floor level, insulation, waterproofing, structural support and drainage can change the frame, threshold or final manufacturing size.
HOW TO READ THE DATA
Six values that shape the result.
A catalogue maximum is not the rating of every fabricated element. Classes depend on size, opening scheme, glazing, hardware and the tested configuration.
SYSTEM SELECTION
We compare HI+ with the alternatives for your project.
Send façades, plans or an opening schedule. We will verify whether HI+ is justified, what glazing achieves the target Uw and how the installation perimeter should be built.
Send project ↗