Reynaers Aluminium / Aluminium windows & doors

MasterLine 8

A versatile high-performance Reynaers platform for thermally insulated aluminium windows and doors with extensive design and opening options.

MasterLine 8 — Aluminium windows & doors

KEY PARAMETERS

What matters at specification stage.

Assess MasterLine 8 on the actual sash format.

Installation depth

77 mm

Visible width

from 97 mm

Frame Uf

up to 1.0 W/m²K

Element Uw

up to 0.88 W/m²K

Infill / glazing

up to 72 mm

Max. height

up to 2800 mm

Max. vent weight

up to 300 kg

Air permeability

class 4

Watertightness

E900

Wind resistance

C5

Sound insulation

up to 46 dB

Visible frame width, glass weight, hinge type and the real Uw of the element matter more than a theoretical catalogue maximum. The fact that a system can reach a certain limit does not mean every opening should use that configuration.

PROFILE CROSS-SECTION

MasterLine 8 profile geometry in detail.

This image shows the system's profile geometry, chambers, thermal breaks and glazing zones. The final junction is selected for the opening scheme, glass build-up, dimensions and project loads.

Reynaers Aluminium MasterLine 8 profile cross-section
OFFICIAL PROFILE SECTION / SYSTEM CUTAWAY

ARCHITECTURAL CAPABILITY

Why we consider this system.

01

Functional, Hidden Vent, Renaissance and Deco designs

02

Watertightness up to E900 in tested configurations

03

Wind resistance up to C5

04

RC2 / RC3 and fire-rated variants

SYSTEM CONTEXT

* Reynaers figures relate to defined MasterLine 8 test assemblies. In a project, we tie them back to the selected size, glass and hardware.

With MasterLine 8, glass, sash geometry and frame position drive the final result.

Our engineering approach ↗

BIFORIUM / PRACTICE

A system only works as a whole with glass, hardware and installation.

Installation position, support, insulation, sealing and drainage belong in the specification rather than being improvised on site.

Open engineering details ↗
Glazing

Glazing is selected from actual Uw, solar, acoustic and safety requirements; large vents are also checked for glass weight.

Hardware

Hardware limits the viable vent geometry just as much as the profile. Concealed hinges and automation need early coordination.

Installation detail

Installation position, support, insulation, sealing and drainage belong in the specification rather than being improvised on site.

FAQ / SPECIFICATION

Questions to close before specification.

Can the system be selected only from catalogue performance?

No. Published values help shortlist options, but the finished element still has to be checked for size, glazing, weight, hardware, loads and installation detail.

Does every opening need the same glazing build-up?

Not necessarily. A south-facing elevation, a bedroom near traffic, a large fixed pane and an entrance leaf can require different glazing within the same project.

When should the installation detail be coordinated?

Before the final order. Finished-floor level, insulation, waterproofing, structural support and drainage can change the frame, threshold or final manufacturing size.

HOW TO READ THE DATA

Six values that shape the result.

A catalogue maximum is not the rating of every fabricated element. Classes depend on size, opening scheme, glazing, hardware and the tested configuration.

Ufthermal transmittance of the frame
Uw / Udthermal transmittance of the complete window or door
Rwsound reduction index in dB
RCburglary-resistance class
Air / Waterairtightness and driving-rain resistance
Windwind pressure and permitted deflection

START A PROJECT

We select the system around the architecture.

Show the largest opening sashes and a few typical windows. We will check where MasterLine 8 works without unnecessary over-specification and where another configuration is preferable.

Send project ↗