Reynaers Aluminium / Aluminium sliding systems

MasterPatio

A premium Reynaers sliding and lift-and-slide system for large vents, low thresholds and high thermal and weather performance.

MasterPatio — Aluminium sliding systems

KEY PARAMETERS

What matters at specification stage.

Read MasterPatio through panel weight, threshold geometry and drainage.

Element Uw

up to 0.8 W/m²K

Max. vent size

up to 3600 × 3600 mm

Max. vent weight

up to 600 kg

Max. fixed-glass weight

up to 1200 kg

Air permeability

class 4

Watertightness

E1200

Wind resistance

C5

Sound insulation

up to 44 (-1; -4) dB

Barrier-free threshold

0 mm

System type

lift-and-slide

With an HST, the main risk is rarely in the middle of the frame. Rollers, continuous support, finished floor level and the route for external water around the threshold matter more.

PROFILE CROSS-SECTION

MasterPatio profile geometry in detail.

This image shows the system's profile geometry, chambers, thermal breaks and glazing zones. The final junction is selected for the opening scheme, glass build-up, dimensions and project loads.

Reynaers Aluminium MasterPatio profile cross-section
OFFICIAL PROFILE SECTION / SYSTEM CUTAWAY

ARCHITECTURAL CAPABILITY

Why we consider this system.

01

Slim and Functional designs

02

Watertightness up to E1200 in declared configurations

03

Open Corner and 3-rail variants

04

Concealed drainage and automation options

SYSTEM CONTEXT

* Reynaers data describes specific MasterPatio configurations. The final element varies with track scheme, panel size, glass and the lower junction.

MasterPatio works best when the bottom detail is designed together with the terrace.

Our engineering approach ↗

BIFORIUM / PRACTICE

A system only works as a whole with glass, hardware and installation.

Threshold support, finished-floor level and linear drainage must be coordinated before the unit is ordered.

Open engineering details ↗
Glazing

For large sliders, glazing is not only about Ug: weight, solar factor, heat treatment and laminated layers directly affect hardware and installation.

Hardware

Manual or motorised hardware is selected after checking the real sash weight and operating scenario.

Installation detail

Threshold support, finished-floor level and linear drainage must be coordinated before the unit is ordered.

FAQ / SPECIFICATION

Questions to close before specification.

Can the system be selected only from catalogue performance?

No. Published values help shortlist options, but the finished element still has to be checked for size, glazing, weight, hardware, loads and installation detail.

Does every opening need the same glazing build-up?

Not necessarily. A south-facing elevation, a bedroom near traffic, a large fixed pane and an entrance leaf can require different glazing within the same project.

When should the installation detail be coordinated?

Before the final order. Finished-floor level, insulation, waterproofing, structural support and drainage can change the frame, threshold or final manufacturing size.

HOW TO READ THE DATA

Six values that shape the result.

A catalogue maximum is not the rating of every fabricated element. Classes depend on size, opening scheme, glazing, hardware and the tested configuration.

Ufthermal transmittance of the frame
Uw / Udthermal transmittance of the complete window or door
Rwsound reduction index in dB
RCburglary-resistance class
Air / Waterairtightness and driving-rain resistance
Windwind pressure and permitted deflection

START A PROJECT

We select the system around the architecture.

Send the opening size, panel scheme and a floor section at the terrace. That is enough to start reviewing MasterPatio for weight, threshold and drainage.

Send project ↗