INSTALLATION TECHNOLOGY / BIFORIUM

INSTALLATION QUALITY CONTROL

Quality is best checked in stages while supports, anchors and membranes remain visible. A finished photograph does not reveal the concealed envelope.

INSTALLATION QUALITY CONTROL

CONTROL

Junction control points.

01

Before installation

Opening, levels, base, completeness and handling route.

02

Before closing the joint

Supports, anchors, geometry, clearances, internal and external control layers.

03

After glazing

Blocks, compression, beads, gaskets, sash movement and locks.

04

Before handover

Drainage, clean chambers, protective films, photographs and adjustment list.

DETAILS

Related details.

FAQ

Questions from site.

Is checking frame level enough?

No. Diagonals, plane, supports, clearances, fixings and operation after glazing also matter.

Why photograph concealed work?

Anchors, membranes and supports cannot be seen after finishes. Photographs improve control and future service.

When should final adjustment happen?

After wet trades and structural stabilisation, before handover, and again after a season where required.

SITE / START

Have a section or junction photograph?

Send wall build-up, levels and the largest element. We will identify the missing inputs for a working detail.

Review the junction ↗