Modules and logistics
Coordinate module sizes with the facade grid, transport, lifting and installation sequence. Workshop preparation requires interfaces to be resolved in advance.
REYNAERS ALUMINIUM / Unitised curtain walls
A Reynaers unitised curtain wall with 75 mm sightlines for modules prepared in the workshop. This glazing-bead variant is called Functional on the Ukrainian site and Glazing Bead on the global site.

SPECIFICATIONS
| Interior / exterior sightline | 75 / 75 mm |
|---|---|
| Minimum mullion depth | 169.5 mm |
| Minimum transom depth | 169.5 mm |
| Maximum element height (UA sheet) | 3700 mm |
| Element width (UA sheet) | 1000–2700 mm |
| Glazing thickness (UA sheet) | 26–63 mm |
| Glazing rebate height (UA sheet) | 12.5 mm |
| Profile Uf — best catalogue value | 1.3 W/m²K |
| Air tightness | AE1200 (1200 Pa) |
| Water tightness | RE1200 (1200 Pa) |
| Wind load resistance | 2400 Pa |
| Acoustic performance Rw(C;Ctr) | 43(−2;−4) dB |
The figures apply to Functional / Glazing Bead. Uf = 1.3 W/m²K is the best catalogue profile value, not the Ucw of the complete curtain wall. Element dimensions, glazing range and rebate height come from the Ukrainian sheet. Check dimensional limits together with glass weight, loads and supports; maximum figures cannot automatically be combined in one module.
Performance depends on dimensions, profile combinations, hardware and glazing. Each opening requires its own specification; catalogue maxima are not a guarantee for every element.
Variant-specific sources are linked below. Dimensions available only in the Ukrainian technical sheet are identified in the table.
Variant availability, hardware and delivery terms in Ukraine must be confirmed for the project. A catalogue listing does not imply stock availability.
DESIGN CHECKS
Coordinate module sizes with the facade grid, transport, lifting and installation sequence. Workshop preparation requires interfaces to be resolved in advance.
Check module joints, seals, drainage and permitted slab movement. These connections are essential to envelope performance after installation.
Calculate Ucw for the selected configuration. Choose solar control, safety glass and acoustic performance for the building requirements, not only the profile’s best value.
START A PROJECT
Send the opening dimensions, elevations and intended opening types. We will review glazing, hardware and installation requirements together.
Send your project ↗