Separate from CS 77 windows
The Functional door leaf is 68 mm deep; the window version has different geometry. A shared series name does not make their specifications interchangeable.
REYNAERS ALUMINIUM / Aluminium doors
A thermally broken Reynaers door system with a 68 mm frame. The Functional variant provides a glazed entrance with dedicated door geometry, requiring checks for daily operating loads and perimeter sealing.

SPECIFICATIONS
| Frame depth | 68 mm |
|---|---|
| Door leaf depth | 68 mm |
| Min. frame–leaf sightline, inward opening | 144 mm |
| Leaf width, catalogue range | 500–1400 mm |
| Max. leaf height | 3000 mm |
| Uf — best catalogue value | 1.8 W/m²K |
| Ud — reference door below | 1.4 W/m²K |
| Air tightness | 4 (600 Pa) |
| Water tightness | 7A (300 Pa) |
| Wind load resistance | C2 (800 Pa) |
| Acoustics Rw(C;Ctr) | 41(−1;−4) dB |
Ud = 1.4 W/m²K refers to a single inward-opening door: 1.23 × 2.18 m, Ug = 1.0 W/m²K, warm-edge spacer, 150 mm sightline and 36 mm glazing. This is not the minimum 144 mm sightline combination. Ud describes the complete door and Uf the profile; window Uw is not substituted here.
Performance depends on dimensions, profile combinations, hardware and glazing. Each opening requires its own specification; catalogue maxima are not a guarantee for every element.
The table follows the manufacturer’s exact door variant. The global technical sheet supplies Ud and its reference conditions; the Ukrainian sheet is also linked.
Variant availability, hardware and delivery terms in Ukraine must be confirmed for the project. A catalogue listing does not imply stock availability.
DESIGN CHECKS
The Functional door leaf is 68 mm deep; the window version has different geometry. A shared series name does not make their specifications interchangeable.
Before ordering, agree the opening direction, clear passage, hinges, lock and closer. Check the complete leaf weight against the chosen glazing and hardware; no unverified weight limit is stated.
Fire-resistant, bullet-resistant and panel doors require their own profiles, infill and documentation. Functional specifications do not establish those properties.
START A PROJECT
Send the opening dimensions, elevations and intended opening types. We will review glazing, hardware and installation requirements together.
Send your project ↗